GasAlertMicro 5
Five-Gas Detector for H2S, CO, O2,
SO2, PH3, NH3, NO2, HCN, Cl2, ClO2, O3 and Combustibles
With a comprehensive range of features and functions, GasAlertMicro 5 has set a new benchmark in multi-gas detection. At just 7.3 oz., the rugged GasAlertMicro 5 is unrivalled in performance and value-added affordability.
GasAlertMicro 5 portable gas detector simultaneously monitors and displays up to five potential atmospheric hazards including oxygen, combustible gases and a range of toxic gases. Compact and lightweight, GasAlertMicro 5 adds multi-gas detection to our water-resistant line of detectors. Audible, visual and vibrator alarms activate in the event of a low, high, TWA or STEL alarm condition. An optional motorized pump is available.
Beyond features that come standard such as confidence beep, full function self test, automatic calibration and passcode protection, GasAlertMicro 5 offers an extended selection of user-settable field options now including: stealth mode, backlight options, selectable ppm resolution, STEL / TWA measurement choice, combustible correction factor options, user-settable calibration gas concentrations and multi-language support.
Specifications
| Gas | Measuring range | Resolution | TWA | STEL | LOW | HIGH |
|---|---|---|---|---|---|---|
| O2 | 0-30.0% | 0.1 | N/A | N/A | 19.5 | 23.5 |
| CO | 0-999 ppm | 1.0 | 35 | 50 | 35 | 200 |
| H2S | 0-300 ppm | 1.0 | 10 | 15 | 10 | 15 |
| PH3 | 0-5.0 ppm | 0.1 | 0.3 | 1.0 | 0.3 | 1.0 |
| SO2 | 0-100 ppm | 0.1 | 2.0 | 5.0 | 2.0 | 5.0 |
| NO2 | 0-99.9 ppm | 0.1 | 2.0 | 5.0 | 2.0 | 5.0 |
| HCN | 0-30.0 ppm | 0.1 | 4.7 | 10.0 | 4.7 | 10.0 |
| Cl2 | 0-50. ppm | 0.1 | 0.5 | 1.0 | 0.5 | 1.0 |
| NH3 | 0-100 ppm | 1.0 | 25 | 35 | 25 | 50 |
| ClO2 | 0-1.00 ppm | 0.01 | 0.1 | 0.3 | 0.1 | 0.3 |
| O3 | 0-1.00 ppm | 0.01 | 0.1 | 0.1 | 0.1 | 0.1 |
| LEL | 0-100% LEL, 0-5% v/v | 1% High Range Resolution | N/A | N/A | 10% | 20% |
| DETECTOR | |
|---|---|
| Detector: | 1-, 2-, 3-, 4-, or 5-gas detector |
| Auto zero: | Yes |
| Calibration: | Automatic |
| Backlight: |
|
| Sensors: | Plug-in, electrochemical cell (toxic and oxygen); catalytic (LEL) |
| User Field options: | Confidence beep, set STEL period, force calibration on start-up, enable / disable sensor, pass code protection, latching alarms, span level, passed calibration user-lockout option, "SAFE" display function, stealth mode, fast pump, oxygen auto-cal on start-up, alarm only backlight mode, combustible gas measurement (% LEL or % by volume methane), LCD language option, STEL calculation choice, TWA calculation choice, combustible correction factor options, user-settable calibration gas level, clock |
| Alarms and Indicators | |
| Alarms Indicators: | Clearly advises alarm levels with audible, visual, and vibrator alarms |
| Visual alarms: | Two flashing alarm bars visible from all angles LCD advises gas present and alarm level encountered |
| Audible alarm: | Typically 95 dB at 1 ft. / 30 cm variable pulsed audible alarm |
| Vibrator alarm: | Pulses warning in all gas alarm conditions, or for any status alarms |
| Status alarms: | Low battery, over range, multiple gas / pump and failed or missing sensor |
| Alarm Levels: | Instantaneous Low Alarm for all gases; Instantaneous High Alarm for all gases; TWA (time-weighted average) and STEL (short-term exposure limit) for toxics |
| LCD | |
| LCD: | Continuous, alphanumeric gas readout and status display advises: |
| Gases monitored: | H2S, CO, O2, SO2, PH3, NH3, NO2, HCN, Cl2, ClO2, O3 and/or combustibles (0-100% LEL or 0-5.0% v/v methane) |
| Gas concentration: | Simultaneously and continuously displays gas concentration(s) for all sensors (in ppm, % LEL, or % v/v) |
| Peak (max) / STEL / TWA ppm or %: | Records exposures and displays on demand |
| Alarm Setpoints: | Displayed on activation and on demand |
| Calibration due date: | In days remaining (on start-up) |
| Clock: | Real-time clock setting displayed on start-up |
| TESTs | |
| Full function self-test: | Sensor integrity, circuitry, battery and audible / visual alarms on activation |
| Battery: | Continuous |
| General Specs | |
| General Specifications: | Rugged, composite material; two-shot molded polymer case with integral anti-shock boot |
| Operating temperature: | -4º to +122º F (-20º to +50º C) |
| Humidity: | 5% to 95% RH (non-condensing) |
| EMI/RFI: | Complies with EMC Directive 89/336/EEC |
| Protection: | Highly water resistant and dust proof housing |
| Battery options: | 23 hours on three AA alkaline cells or 20 hours on rechargeable "hot-swappable" battery pack when equipped with oxygen, combustible, TwinTox (H2S / CO) and one additional toxic sensor |
| Size: | 5.7 x 2.9 x 1.5 in. / 14.5 x 7.4 x 3.8 cm. |
| Weight: | 13.1 oz. / 370 g |
| Warranty | |
| Warranty: | Full 2-year warranty including all sensors (1 year NH3 sensor) |
| Datalogger Options | |
| Datalogger Options: | User downloadable datalogger |
| Data recorder: | All events and occurrences (calibration zero adjustment, calibration span adjustment, gas readings, TWA, STEL, alarm condition, failures detected by the microprocessor). |
| Sampling rate: | Factory set at 5-second intervals and user-settable from 1 to 127-second intervals |
| Storage capacity: | Two months of continuous data at 5 second intervals via 32 MB Flash MMC card (64 MB and 128 MB cards also available); when full, the wrap-around feature replaces oldest data with most recent data |
| Pump: | Tubing length up to 100 ft. / 30 m (50 ft. / 15 m standard) with user options |
| Ratings and certifications | |
| Ratings and Certifications: (intrinsic safety) | Classified to US and Canadian Standards by CSA: Class 1, Div. 1, Groups A. B. C. D American Bureau of Shipping (in progress) |
| ATEX: | CE II 1 G T4 Eex ia IIC T4 |
| IECEx: | EX ia IIC T4 |
Due to ongoing research and product improvement, specifications are subject to change without notice.
Downloads
Key Features
- Smaller and over 50% lighter than competitive instruments
- Water-resistant design in an integral concussion-proof enclosure
- Continuous LCD shows simultaneous gas concentrations for five gases
- Integral motorized pump option for remote sampling
- Two power options: AA alkaline or rechargeable hot-swappable battery packs
- Provides 95 dB alarm tone and two bright wide-angled alarm bars
- Equipped with internal vibrating alarm for high noise areas
- Multi-language support in English, French, German, Spanish and Portuguese
- Three backlight options:
standard - activates in low light (auto), in alarm (auto) and reactivates on-demand;
alarm only - activates in alarm conditions and reactivates on-demand;
stealth mode - Four alarm levels: instantaneous Low and High Alarm for all gases;
TWA (time-weighted average) and STEL (short-term exposure limit) for toxic gases - Simple automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station
- Records TWA, STEL, and maximum exposures to gas and displays readings on command
- User selectable field options include: language selection, confidence beep, span level, set TWA / STEL calculation choice, set calibration due date, pass code protection, latching alarm, "SAFE" display function, stealth mode, and selectable ppm resolution for some gases (e.g., SO2 0.1 ppm)
- Full function self-test of: sensor, battery and circuit integrity; and audible/visual alarms
Copyright © 2006 by Manning Systems Incorporated. All rights reserved.