GasAlertClip Extreme
Disposable Portable Single Gas Monitor for H2S, O2, CO or SO2
The GasAlertClip Extreme is highly water-resistant, with an IP-66 / 67 housing fully immersible to a depth of three feet (one meter). The GasAlertClip Extreme housing includes an integral concussion-proof boot, a heavy-duty stainless steel alligator style belt-clip. A large easy-to-read LCD shows detector life remaining, alarm setpoints, peak alarm exposures, and other information.
When the START/TEST button is pushed, the GasAlertClip Extreme is ready for use for two years of continuous protection for H2S, oxygen, carbon monoxide or sulfur dioxide exposure. A full function self-test verifies sensor, circuitry and battery integrity, as well as function of the audible, visual and vibrator alarms. The GasAlertClip Extreme can transmit stored event data directly to a PC or thermal printer. Simply attach the IR adapter to your computer’s USB port and push the button to download the stored information.
Industrial applications include Oil and Gas (drilling and production), Utilities and Municipalities, Refineries and Petrochemical Facilities, Steel Mills, Pulp and Paper, Marine / Shipping, and General Industry (construction, military, mining and chemical facilities).
Specifications
| Gas monitored | H2S | CO | SO2 | O2 |
|---|---|---|---|---|
| Sensor range | 0-100 ppm | 0-300 ppm | 0-100 ppm | 0-30.0% by vol |
| Low alarm level | 10 ppm | 35 ppm | 5 ppm | 19.5% |
| High alarm level | 15 ppm | 200 ppm | 10 ppm | 23.5% |
| Operating temp | -40º to +122ºF | -22º to +122ºF | -22º to +122ºF | -4º to +122ºF |
| Calibration | Not required | Not required | Not required | Self-calibrating |
Notes: Customized alarm settings available at no charge. Internal vibrator operates down to +5º F
| General Specs | |
|---|---|
| General Specs: | Rugged composite material with integral concussion-proof boot |
| Humidity: | 5% to 95% RH (non-condensing) |
| EMI/RFI: | Complies with EMC Directive 89/336/EEC |
| Ingress protection: | IP 66/67 |
| Battery: | Lithium, non-replaceable |
| Continuously On: | Yes |
| One-button control: | Activation, self-test and alarm event data transmission |
| Full Functional self-test: | Verifies integrity of sensor, circuitry, battery and audible/visual Alarm |
| Sensor: | Electrochemical cell (temperature compensated) |
| Operational Life: | Two years |
| Indicators and Alarms | |
| Visual Alarm: | Flashing, wide-angled alarm lens with quad red LEDs, plus ALARM LCD readout |
| Audible Alarm: | Pulsing, high-output siren at 95 dB (typical) @ 1 ft. (0.3 m) |
| Vibrator alarm: | Internal |
| Failure alarm: | Yes (audible / visual / vibration) |
| Self-test pass: | Yes (audible / visual / vibration) |
| Other: | End of life (audible / visual / vibration) |
| LCD | |
| Continuous LCD Display: | Status display |
| Life remaining: | Continuously displayed in months, then days, then hours |
| Two alarm levels: | LOW alarm / HIGH alarm |
| Peak alarm exposure: | Records and displays peak alarm exposure, and time elapsed (up to 24 hours) |
| Alarm setpoints: | High and Low (displayed on demand in ppm or %) |
| Self-test status: | Advises to "TEST" and that self-test was passed |
| Tests | |
| Full function self-test: | On activation and on-demand |
| Battery: | Every two hours (auto) |
| Event Logging: | Records and transmits up to 10 gas alarm events |
| Event Information: | Gas type, peak exposure level (ppm or %), alarm duration in minutes and seconds; time elapsed since the alarm occurred in days, hours and minutes, life remaining, self-tests, cumulative alarm time |
| Transmission method: | Via infrared port to infrared printer or to an IR datalink |
| Physical Size: | |
| Size: | 1.1 x 2.0 x 3.2 inches / 28 x 50 x 81 mm |
| Weight: | 2.7 oz. / 76 g |
| Warranty: | Two years from activation, plus 1-year shelf life (given 3-5 minutes of alarm per day in normal operation) |
Due to ongoing research and product improvement, specifications are subject to change without notice
| Ratings and certifications | |
|---|---|
| Ratings and Certifications: | UL Class 1, Div. 1, Gr. A, B, C, D Class 1, Zone 0, Gr. 11C American Bureau of Shipping |
| ATEX: | CE 11 1 G E Ex ia IIC T4 |
| IECEx: | Ex ia IIC T4 |
Downloads
Key Features
- Two years of protection with zero maintenance costs
- Continuous, alphanumeric status LCD shows detector life remaining, alarm setpoints and advises self-test status
- Rugged IP-66/67 highly water-resistant design
- Built-in concussion-proof boot
- Records and displays the peak alarm encountered and the time elapsed since the exposure occurred
- Automatic event logging records 10 most recent alarm events that can be downloaded via infrared port
- Two alarm levels (Low / High)
- Provides typical 95 dB tone and bright, quad-LED indication on alarm
- Internal vibrator alarm
- Small size (1.1 x 2.0 x 3.2") and lightweight (2.7 oz.)
- Maintenance free – no sensor or battery replacement, no calibration, no downtime
- Full-function self-test of audible/visual alarms, plus integrity of sensor, battery and circuitry
- Continuously ON – one-button activation, test and data transmission
- Comes complete with rugged, stainless steel alligator belt clip and test cap
- Superior RFI protection
- Instruction in local languages included
Copyright © 2006 by Manning Systems Incorporated. All rights reserved.
Manning Systems is a Honeywell Company.