Banana and Produce Rooms
Banana Rooms and Produce Coolers are the main reasons that Manning Systems pioneered the use of electrochemical sensors for detecting ammonia in these difficult areas. Many years and thousands of sensors later, electrochemical technology is still the best answer for low ppm "no-false-trip" sensing in banana storage and produce coolers. The EC-F9-NH3 electrochemical sensor is specific to ammonia, i.e., will not trip on ethylene or other gases, and operates for several years between cell replacement with minimal maintenance.
The IR-NH3 infrared sensor will sense only ammonia and can be relied on for accurate, repeatable information when used for high level ammonia sensing or electrical shutdown.
If halocarbon refrigerants are used, the AirScan™ iR infrared refrigerant sensor won't false trip when exposed to the mixture of gases typically found in either of these applications.
A diffusion-type system has many advantages in cold or wet environments of food processing and storage. With the information transmitted by wire continuously in real time, there is no danger of pumping water back to a central analyzer or the possibility of diluting the gas sample, as would be typical of a sample draw system installed in a wet environment. Ice formation in the sample draw tubing can block the return lines and totally disable the system.
Related products and technology
Manning Systems enclosures with optional ATMOS equipped® technology (Adaptive Temperature and Moisture Optimizing System) feature the first enviro-adaptive technology available for gas sensors. Manning Systems electrochemical and infrared gas sensors with ATMOS equipped® technology can automatically adapt to environments from -50°F to 100% humidity and washdown conditions, assuring industry leading performance in the harshest environments.
All Manning Systems sensors can be monitored by the GM-1 single channel gas monitor or the GM-10 or GM-4 multi-channel gas safety systems that provide an individual bargraph display of gas concentration for each channel, plus relay outputs for emergency response and ventilation control. The redundancy provided by a Manning Primary Safety System (MPSS) gives an extra measure of gas monitoring protection and peace of mind.
The new AirAlert 96d multi-channel gas monitoring system adds addressable RS-485 Modbus communication protocol to the broad line of Manning Systems readout/alarm units. A total of 96 gas sensors and relay modules can be linked to a single controller.
Manning Systems offers personal protection portables for the single- and multi-sensor toxic gas detector market. These innovative, low-cost portables are ideal for industrial hygienists, safety managers, petrochemical applications, fire departments, police and emergency responders at risk of exposure to toxic contaminants.
Copyright © 2006 by Manning Systems Incorporated. All rights reserved.
Manning Systems is a Honeywell Company.